Builder fined $80,000 over fall risks at two townhouse sites

10 Mar 2025•BlueSafe Team•Source: WorkSafe VIC

Schintta Building Group Pty Ltd has been fined $80,000 after workers were exposed to fall risks at two townhouse developments. The company was found guilty of five charges of failing to provide a safe workplace.

The Ringwood Magistrates' Court sentenced the company ex parte on Thursday 13 February. It imposed fines of $30,000 for three charges concerning the McKenzie Street site and $50,000 for two charges at the Elizabeth Street development. The company was also ordered to pay $5068 in costs.

The court heard that WorkSafe inspectors visited the two-storey McKenzie Street townhouse development in October 2022 and found housekeeping problems and subcontractors working more than three metres above ground on scaffolding with missing planks and guardrails. Platforms over internal stair voids were made from framing timber and particle board that could collapse under workers' weight. An unsecured ladder provided access to the second storey.

To move between split-level slabs at McKenzie Street, workers climbed up and jumped down about 1.5 metres. Alternatively, they used a makeshift ramp consisting of a timber plank only about 25 centimetres wide.

Inspectors found similar housekeeping and fall-risk issues at Elizabeth Street in May 2023, where four double-storey townhouses were being built. Workers were about six metres above ground on scaffolding missing guardrails, planks and a scaffold tag. Lap boards were unsecured, and gaps between the scaffold and the townhouses exceeded 225 millimetres.

All four townhouses had unprotected open stair voids. Workers reached the second storeys using an unsecured A-frame extendable ladder without a 900 millimetre overhang.

The court found the company should have reduced fall risks at both sites through solid construction for work at height, passive protection such as perimeter guardrails, or a fall arrest system such as harnesses. It should also have installed stair void protection and a secured ladder. At McKenzie Street, a reasonably practicable system for crossing the split-level slabs would have prevented workers from using an unsecured plank and provided a secured plank and/or level stairs with a secure handrail and appropriately sized treads.

WorkSafe Executive Director of Health and Safety Sam Jenkin said it was incredibly disappointing that workers had repeatedly been placed in dangerous situations at both sites. "Falls from height do not discriminate and sadly remain one of the biggest causes of death and serious injury in the Victorian construction industry, claiming 10 lives in the past three years alone," Mr Jenkin said. "The ways to properly manage the risk of falls are no secret and readily available so employers have absolutely no excuses if they leave their workers at risk."

WorkSafe's advice to employers is to use the highest possible measures from the five levels of the hierarchy of controls to prevent falls from height.

How Blue Safe can help: Our free SWMS tool can help you document fall hazards and control measures for high-risk construction work. Create a free SWMS