This risk assessment covers activities associated with high voltage electrical installations, including planning, isolation, switching, work near equipment, testing and close-out.

Activities covered include

  • Review the installation, supply arrangement, energy sources, worker authorisation and access routes
  • Identify and manage cables, terminations, underground services and cable-handling hazards
  • Check PPE, remove residual tools and materials, control re-access and update records

Download immediately

Your editable Word and PDF files are ready to download after purchase.

Acceptance guaranteed

If your client or principal requests changes during document review, BlueSafe will help revise the document at no extra cost and support resubmission until it is accepted.

High Voltage Electrical Installations Risk Assessment
  • 100% Compliant with Australian WHS Acts & Regulations
  • Fully Editable MS Word & PDF Formats Included
  • Pre-filled Content - Ready to Deploy Immediately
  • Customisable - Easily Add Your Logo & Site Details
  • Includes 2 Years of Free Compliance Updates

Product Overview

This risk assessment covers activities associated with high voltage electrical installations, including planning, isolation, switching, work near equipment, testing and close-out. It supports task planning by identifying electrical, arc flash, access, plant, cable and emergency response hazards for risk management.

Activities & Risks Covered

This assessment addresses activities and risks including:

  • Review the installation, supply arrangement, energy sources, worker authorisation and access routes
  • Set up site access controls, barricading and housekeeping around high voltage areas
  • Isolate, lock and prove equipment de-energised while managing stored or induced voltage
  • Plan and communicate switching activities, work positions and switching sequences
  • Manage work on or near high voltage equipment, open enclosures and restricted work positions
  • Identify and manage cables, terminations, underground services and cable-handling hazards
  • Control nearby plant, lifting operations, mobile equipment and ground-penetration activities
  • Manage inspection, testing, commissioning and return-to-service activities
  • Prepare for electric shock, burns, arc flash, evacuation and emergency response
  • Check PPE, remove residual tools and materials, control re-access and update records

Who is this for?

Suitable for contractors, workers, supervisors and businesses carrying out activities involving high voltage electrical installations.

Activities & Hazards Covered

Activity Potential Hazards
Planning and pre-start review
  • Incorrect understanding of the high voltage installation or supply arrangement
  • Unidentified energy sources, backfeeds or induced voltages
  • Workers attending without the required high voltage competency or authorisation
  • Plant or access routes entering hazardous areas
Site access and work area set-up
  • Unauthorised entry into high voltage areas
  • Exposure to live parts due to poor separation or inadequate barricading
  • Vehicle or plant intrusion into restricted areas
  • Slips, trips and poor housekeeping around switch rooms, substations or cable routes
Isolation, locking and proving de-energised
  • Electric shock, arc flash or burns from failure to isolate all sources
  • Unexpected energisation from remote switching, backup supply or incorrect identification
  • Contact with exposed conductors during testing
  • Stored, induced or capacitive voltage remaining after isolation
Switching and high voltage operating activities
  • Arc flash, blast pressure and flying debris during switching
  • Incorrect switching sequence causing equipment damage or exposure to live parts
  • Workers positioned within the line of fire of doors, covers or switchgear
  • Poor communication between switching personnel and the work party
Work on or near high voltage equipment
  • Direct or indirect contact with energised parts
  • Arc flash from tools, dropped objects or loss of insulation
  • Inadvertent encroachment into unsafe approach distances
  • Injury from open enclosures, sharp edges or restricted work positions
Cables, terminations and underground services
  • Cutting, drilling or disturbing an energised or incorrectly identified cable
  • Electric shock from secondary circuits, induced voltage or damaged cable insulation
  • Arc flash during termination, jointing or testing activities
  • Struck-by or manual handling injury when moving heavy cables or covers
Plant, lifting operations and mobile equipment nearby
  • Contact or flashover from cranes, EWPs, trucks or other plant entering electrical clearances
  • Damage to underground high voltage assets from excavation or ground penetration
  • Workers touching plant that becomes energised
  • Collision with substation structures, fencing or cable risers
Inspection, testing and commissioning
  • Exposure to energised parts during testing or re-energisation
  • Arc flash or equipment failure due to incorrect settings, loose terminations or wrong test method
  • Unexpected operation of connected plant
  • Miscommunication during return to service
Emergency preparedness and response
  • Delayed rescue following electric shock, burns or arc flash
  • Inadequate first aid response for electrical trauma
  • Panic or uncoordinated evacuation after an incident
  • Workers re-entering an unsafe area after a fault event
PPE, housekeeping and close-out
  • Burns or injury due to unsuitable or poorly maintained PPE
  • Residual risk from tools, leads, covers or waste left in the work area
  • Unauthorised re-energisation or access after incomplete close-out
  • Failure to update records following changes or defects found

Need to tailor this risk assessment?

Use the BlueSafe Portal to add site-specific activities, hazards, controls, responsibilities and review details before the assessment is put into use.

Acceptance Guaranteed: If your client or principal requests changes during document review, BlueSafe will help revise the document at no extra cost and support resubmission until it is accepted.

Legislation & References

The template records model guidance used to inform the documented controls. Applicable WHS/OHS laws and adopted Codes vary by state or territory, so confirm the current local requirements when tailoring the assessment:

  • Model guidance: Model Code of Practice: Managing electrical risks in the workplace — 5. Isolation, locking off and access; p. 34.
  • Model guidance: Model Code of Practice: Managing the work environment and facilities — 2. The work environment; p. 13.
  • Model guidance: Model Code of Practice: Excavation work — 2.3. Controlling the risks; p. 17.
  • Model guidance: Model Code of Practice: Construction work — 6.2 Workplace specific induction training; p. 41.
  • Model guidance: Model Code of Practice: First aid in the workplace — 3. First aid equipment, facilities and training; p. 12.
  • Model guidance: Model Code of Practice: Confined spaces — 3.4 Assessing the risks; p. 24.
  • Model guidance: Model Code of Practice: Managing risks of plant in the workplace — 4.1 Guarding plant; p. 39.
  • Model guidance: Model Code of Practice: Hazardous manual tasks — 4.1 The hierarchy of control measures; p. 31.

Standard Risk Assessment Features (Click to Expand)
  • Activity-specific hazard identification and control measures
  • Initial and residual risk ratings
  • Assigned responsible persons for each activity
  • Risk matrix and assessment classification
  • Review, monitoring and sign-off fields